DEADLINE: 18TH JULY, 2025
FINAQUEST INTEGRATED RESOURCES LIMITED
REQUEST FOR QUOTATION (RFQ) FOR THE PROCUREMENT OF ENERGY AUDIT EQUIPMENT
An organization of interest is seeking to engage the services of reputable and qualified companies to procure Energy Audit equipment for the purpose of powering tertiary health institutions across multiple states. Interested companies are hereby invited to submit their quotations for the specifications below:
| Quantity | Code Name | Description |
|---|---|---|
| Fluke 1732 | Voltage: 1000V Range 0.1V Resolution ±(0.2%+0.01%) Intrinsic Accuracy | |
| Current with i17xx-flex 1500 12″ 150A 0.1A ±(1%+0.02%) | ||
| 1500A 1A ±(1%+0.02%) | ||
| Frequency: 42.5Hz to 69Hz 0.01Hz ±(0.1%) | ||
| Auxiliary Input: ±10V dc 0.1mV ±(0.2%+0.02%) | ||
| Voltage Min/Max: 1000V 0.1V ±(1%+0.1%) | ||
| Battery: Li-ion 3.7V, 9.25Wh, Customer-replaceable | ||
| On-battery runtime: Four hours in standard operating mode, up to 5.5 hours in power saving mode | ||
| Charging time: < 6 hours | ||
| Circuit types: 1-Ø, 1-Ø IT, Split phase, 3-Ø delta wye IT, 3-Ø wye balanced, 3-Ø Aron/Blondel (2-element delta), 3-Ø delta open leg, currents only (load studies) | ||
| Data storage: Internal flash memory (not user replaceable) | ||
| PV150 | Display Range 30V-440VAC/DC | |
| Voltage Measuring Range 30V-440VDC, 30V-440VAC 50-60Hz | ||
| Resolution: 1V | ||
| Accuracy: ±(5%+2 digits) | ||
| Current Measuring Range: 0.1A-40.0ADC, 0.1A-40.0AAC 50-60Hz | ||
| Display Range: 0.05MΩ-199MΩ | ||
| Measuring Range (EN 61557-2): 0.05MΩ-199MΩ | ||
| Resolution: 0.01MΩ maximum | ||
| Accuracy: 0.05MΩ-100MΩ ±(5%+5 digits), 101MΩ-199MΩ ±(10%+5 digits) | ||
| Connectivity: USB download to PC (CSV format), wireless | ||
| “Solarlink TM” to Survey 200R (range ~30M/100ft), Service: 2 years warranty (subject to terms and conditions, available at /warranty | ||
| Short Circuit Current Measurement (PV Terminals) | ||
| Display Custom LCD with backlight | ||
| Power Source 6x 1.5V AA cells | ||
| Testo 350 MARITIME COMBUSTION | Flue Gas Analyzer Control Unit PI401B1931B-BISMI | |
| Flow Meter | Type: Electromagnetic or Ultrasonic; Accuracy: ±0.2% or better; Pipe Size: 1″ to 80″; Operating Pressure: Up to 2050 bar; Communication: Modbus, HART, RS-485 | |
| Hikvision Thermal Camera | Resolution 640×480 pixel | |
| 50mk sensitivity | ||
| USB, Wi-Fi connectivity |
Eligibility Requirements:
Interested companies must meet the following criteria:
1. Submit Valid tax clearance certificate and other compliance certificates
2. Provide similar job completion documents for jobs done in the past
3. Submit audited account
Timeline:
Interested firms are required to submit their proposals to jelil.olaiya@finaquestconsulting.com no later than one 7 days from the date of this publication. All enquiries should also be directed to the same email address.
Note:
Kindly submit hard copies of your proposals to:
FINAQUEST INTEGRATED RESOURCES LIMITED
Flat 1, Plot 3680, Erie Crescent, Off Nile Street, Maitama District, Abuja